• MEGABOARD the multi-purpose external substrate render cladding system

    MEGABOARD™ External Cladding is a multi-purpose MCB light-weight cladding material providing a stable monolithic substrate for render systems or as a substrate for stone facades.

Non-Combustible Water-Resistant Mould and Mildew Resistant Termite Resistant Impact Resistant

External Cladding

MEGABOARD™ External Cladding

MEGABOARD™ External Cladding is a multi-purpose MCB light-weight cladding material providing a stable monolithic substrate for render systems. Light-weight composite construction is being adopted over masonry construction to reduce costs incurred in material and installation costs. MEGABOARD™ is ideal for exterior residential cladding, 2 story additions or for extensions to existing dwellings. MEGABOARD™ is also compliant with AS 1530.2 and is classified as an A grade non-combustible construction material making it ideal for up to BAL 40 building requirements.

MEGABOARD™ can be fixed to either timber frame construction or steel frame construction and can be provided in straight edge or recessed edging. MEGABOARD™ is available in a range of thicknesses providing complete flexibility for the designer or builder.

Straight EdgeEdging Details – MEGABOARD™ is available with 2 standard edges. All boards under 6mm are straight edge with all other boards available with recessed edging on the long edges. Boards with 4 edges recessed special orders are required.

Chamfered edges

MEGABOARD COATING SYSTEMS/ INTERNAL/EXTERNAL

All substrates need a coating system that protects, enhances and provides excellent aesthetics for the purpose it is being used. ReGen Building Solutions have researched out the best coating products with suppliers for internal and external applications. Wattyl/Solver/Granolite have provided both an internal and external specification and have tested MEGABOARD at their laboratory. The results were excellent providing a custom specification for both internal and external usage.

The link below is the link to their colour charts which will give you a some appreciation of the range although we recommend that you visit their show rooms conveniently located throughout Australia or their distributors. Wattle Store LocatorSolver Colour Designer.

For specifications on internal and external coating please go to Technical or follow this link. MEGABOARD Technical

Thickness mm Length mm Width mm Weight kg Sheets p/pallet Pallet weight ton
4.5 2400 1200 13.6 110 1.5
6 2400 1200 18.1 70 1.27
6 2700 1200 20.6 70 1.44
6 3000 1200 23.1 70 1.64
8 2400 1200 24.2 55 1.33
8 2700 1200 27.4 55 1.5
8 3000 1200 30.7 55 1.69
10 2400 1200 30.7 45 1.38
10 2700 1200 34.3 45 1.54
10 3000 1200 38.4 45 1.73
12 2440 1200 36.9 40 1.48
12 2700 1200 41.1 40 1.64
12 3000 1200 46.1 40 1.84
16 3000 900 45.4 35 1.59
20 3000 900 56.7 30 1.7

For boards of different configurations including width and edging please contact us.

 

Fixing details PLEASE CLICK ON PICTURES FOR CLOSER DETAIL

Eaves and Soffit details

Eaves and Soffit details

Vertical Fixing Detail

Vertical Fixing Detail

Vertical Fixing Joint PVC Joiner

Vdrtical Fixing Joint PVC Joiner

Vertical Fixing Joint nails

Vertical Fixing Joint nails

Vertical Fixing Joint Steel Frame

Vertical Fixing joint steel frame

Control Joint Fixing Detail – Standard Cladding

Control Joint Fixing Detail - Steel Frame Standard Cladding

Control Joint Fixing Detail

Control Joint Fixing Detail

Horizontal Joint – 1st Floor to Block work

Horizontal joint - 1st floor to Block Work

Horizontal Fixing Joint – First Floor

Horizontal Fixing Joint - 1st Floor

Timber Control Joint Fixing Detail

Timber Control Joint Fixing Detail

Steel Control Joint Fixing Detail

Steel Control Joint Fixing Detail

Glazing Jamb Fixing Detail

Glazing Jamb Fixing Detail

Glazing Base Fixing Detail

Glazing Base Fixing Detail

Glazing Head Fixing Detail

Glazing Head Fixing Detail

Board Cutting and Fixing Tables

Location of Cut along External Cladding

External Cladding Sheet Cut Details

 

 

 

 

Fixing of Horizontally Orientated Boards

Fixing of Horizontally Orientated Cladding to Framing

Fixing of Vertically Orientated Boards

Fixing of Vertically Orientated Cladding to Framing

External Cladding Span Tables

MEGABOARD SPAN TABLE 6MM

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 450 200 450 300
N2 450 200 450 300
N3 200 450 300
N4 200 300
N5 200 300
N6 200 300

MEGABOARD SPAN TABLE 8MM

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 450 200 600 300
N4 450 200 450 300
N5 450 200 450 300
N6 200 450 300

MEGABOARD SPAN TABLE 10MM

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 600 200 600 300
N4 600 200 600 300
N5 450 200 600 300
N6 450 200 450 300

MEGABOARD SPAN TABLE 12MM

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 600 200 600 300
N4 600 200 600 300
N5 600 200 600 300
N6 600 200 600 250

MEGABOARD SPAN TABLE 16MM

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 600 200 600 300
N4 600 200 600 300
N5 600 200 600 300
N6 600 200 600 200

MEGABOARD SPAN TABLE 20MM

Wind Classification Within 1200mm of Building Corners Elsewhere Externally
As per AS4055-2012 Max support spacing e.g batten(mm) Max Fastener Spacing (mm) Max support spacing e.g batten(mm) Max Fastener Spacing (mm)
N1 600 200 600 300
N2 600 200 600 300
N3 600 200 600 300
N4 600 200 600 300
N5 600 200 600 300
N6 600 150 600 150